C² Maintenance™

PROTOCOL FOR FLOOR CARE AND PROTECTION

KT- 1.02.2025 Polished Concrete
A

CHECKLIST - DAILY CARE

Procedure before, during and after machine washing.

A & C. PREPARATION AND WASHING

  • Before you turn it on: Mark and delete Mark the "Wet floor" zone. Clean up spills of aggressive liquids / grease (spot at once).
  • Remove dry dirt Acrylic mop / vacuum cleaner / sweeper. Dry dirt (sand/dust) must disappear.
  • Pad selection Put on the right pads: **soft white or red**. No hard pads!
  • Pressure setting Start from **30 kg**. If it doesn't wash, slow down / do 2nd pass. Max 60 kg.
  • Work technique Work with even strips, without "jerking" or long spinning in place. Do not use diamonds.

B. DOSING (COMAC 85B - 110 L tank).

  • Daily Dosage (1:100) Pour **1.1 L (1100 ml)** of C² Maintenance into 110 L of water.
  • Dosing Deeper (1:50) When dirtier, pour **2.2 L (2200 ml)** C² Maintenance into 110 L of water.

D. AFTER WASHING

  • Cleaning the machine Empty the dirty water, rinse out the tanks and working parts.
  • Rinsing the pads Rinse pads and leave to dry (dirty pad = streaks and scratches).
C

CHECKLIST - PERIODIC CLEANING

When and how hard?

We use when you can see the accumulation of gray tarnish despite daily washing. A concentration of 1:50 is standard.

MAX 1:10

Only in extreme cases and locally.
** Dilute in a bucket and apply spot on.

Rule of thumb: We always use the mildest possible dilution that works.

DOSAGE STEPS (Concentration 1:50)

  1. 1)
    Remove dry dirt Acrylic mop / vacuum cleaner / sweeper (as always).
  2. 2)
    Prepare the solution and Pad Concentration 1:50 (2.2 L to COMAC 110 L). Use **red wash pad**.
  3. 3)
    Response time Spread the solution and **wait 10-15 minutes**. Do not allow to dry out!
  4. 4)
    Scrubbing Scrub by machine (**with the squeegee raised and off**). In tougher areas, you can repeat the pass.
  5. 5)
    Collection and Flushing Collect dirty water, then make a "flushing" (neutralization) run.
!

WHAT IS NOT ALLOWED (PROHIBITIONS)

Use of the following substances or tools damages the floor and is grounds for complaint.

1 Forbidden Chemistry

  • Acidic Agents **pH below 7** (pH < 9 changes the natural pH of concrete, which is 11 pH).
  • Strongly Alkaline Prohibit the use of products with a pH **> 11**.
  • Solvents Acetone, toluene, xylene.
  • Other Chemicals Phosphates, salts, Acids (hydrochloric, acetic, citric, phosphoric).

2. forbidden pads/brushes

  • Hard Elements Hard brushes and pads (scratch).
  • Diamond pads **Diamond pads** are not allowed in the C² Maintenance procedure.
  • Black Pads Hard black pads.

3. tapes and stickers

  • Using Resin Glue We do not recommend using tapes and stickers with resin adhesive.
  • ⚠️
    Necessary Test Required test in a low visibility location!

TECHNICAL QUESTIONS?

📞 509 051 511

SALES CONSULTANT

👤 +48 519 087 032

DO YOU WANT TO ORDER?

📱 +48 690 359 394

✉️ zamowienia@decokoncept.pl

© 2025 C² Maintenance Infographic. Based on KT- 1.02.2025 documentation.

**Information for the operator: Remember to check the documentation KT-1.02.2025.**.